威尼斯DG梦幻厅

Reagent Center

Animal Pathogen Series

  • CSFV Real Time RT-PCR Detection kit MORE
    Product Details:

    This kit uses RNA as a template to transcribe and synthesize cDNA strands under the action of reverse transcriptase. Under the action of hot-start polymerase, the qualitative detection of classical swine fever virus is achieved through polymerase chain reaction (PCR) combined with Taqman fluorescent probe technology. The primers and Taqman probes in this kit are designed with specific fragments of classical swine fever virus, which are suitable for auxiliary diagnosis, detection and epidemiological investigation of classical swine fever virus (CSFV) in pig tissues and blood.

    The kit is suitable for all kinds of real-time quantitative detection systems, and is especially suitable for the Line-Gene series fluorescent quantitative PCR detection system of Hangzhou Bioer Technology Co., Ltd

     

    Cat#

    BSL28S1

    BSL28M1

    Components

    24 T

    48 T

    CSFV RT-PCR Buffer

    360 µL

    720 µL

    CSFV Positive control

    200 µL

    200 µL

    CSFV Negative control

    200 µL

    200 µL

    Storage conditions and expiry date

    1. The kit must be shipped under refrigerated conditions.

    2. Preservation of the kit: Store in a refrigerator at -20°C in the dark. Repeated freezing and thawing should not exceed 5 times.

    3. Validity period: 12 months, please use within the validity period

    Product Features:

    1.High specificity: design primers and probes for classic swine fever virus

    2.Wide adaptability: It can be used with Hangzhou Bioer Line-Gene series fluorescent quantitative PCR detection system and similar fluorescent quantitative PCR detection systems of other manufacturers

    3.Simple operation and short time-consuming: Pre-mixed reagents are used, with few components and convenient operation

    4.The results are objective and reliable: use the Ct value to automatically quantify the sample concentration

    Experimental data:

    Use MagaBio plus Virus DNA/RNA Purification Kit II to extract samples containing classical swine fever virus, and perform sensitivity verification after 10-fold serial dilution.

    Result

    CSFV

    Ct Value

    Original liquid

    18.66

    18.51

    10 times dilution

    22.29

    22.28

    100 times dilution

    28.82

    25.7

    1000 times dilution

    29.39

    29.57

    10000 times dilution

    32.96

    32.62

    100000 times dilution

    35.62

    35.77

    Negative control

    NoCt

    NoCt

     

     

     

     

     

    Manual download
  • ASFV Wild Strain and Gene-deleted Vaccine Strain Real Time PCR Dual Detection kit MORE
    Product Details:

    This kit selects specific fragments in the gene sequence of the African swine fever virus wild strain and gene-deleted vaccine strain to design primers and Taqman probes, and through polymerase chain reaction (PCR) combined with Taqman fluorescent probe technology to achieve qualitative detection of African swine fever virus wild strains and gene deletion vaccine strains.

     

    Cat# 

    BSL27S1

    BSL27M1

    Components

    24 T

    48 T

    2×PCR Buffer

    480 µL

    960 µL

    Positive comtrol

    200 µL

    200 µL

    Negative control

    200 µL

    200 µL

    Storage conditions and expiry date

    1. The kit must be shipped under refrigerated conditions.

    2. Preservation of the kit: Store in a refrigerator at -20°;C in the dark. Repeated freezing and thawing should not exceed 5 times.

    3. Validity period: 12 months, please use within the validity period

    Product Features:
    1. Wide adaptability: open reagents, suitable for various quantitative PCR instruments, especially for related quantitative PCR instruments of Bioer company
    2. Simple operation and short time-consuming: Pre-mixed reagents are used, with few components and convenient operation
    3. Objective and reliable results: use Ct value to automatically qualitative samples
    Experimental data:

    Case 1

    Perform sensitivity verification after serial dilution with recombinant plasmids containing the target fragments of ASFV wild strain and gene deletion vaccine strain.

    Ct value

    Sample

    FAM

    HEX

    Sample 1

    38.72

    37.23

    Sample 2

    37.81

    36.33

    Positive

    25.37

    24.38

    Negative

    NoCt

    NoCt

     

    Case 2

    Use MagaBio plus Virus DNA Purification Kit II to extract samples containing wild strains of African swine fever virus, and use the kit to test the extracted products. The results are as follows:

    Ct value

    Sample

    FAM

    HEX

    Sample 1

    38.72

    37.23

    Sample 2

    37.81

    36.33

    Positive

    25.37

    24.38

    Negative

    NoCt

    NoCt

     

    Manual download
  • ASFV real-time PCR detection reagent MORE
    Product Details:

    African Swine fever virus (ASFV) is a double-stranded DNA virus belonging to Asfarviridae, which can cause acute and hemorrhagic symptoms in domestic pigs or wild boar after infection. The virus spreads quickly among pigs and could have serious effects for the breeding industry if it is not detected in time. Bioer ASFV real-time PCR detection reagent series is specially designed for this virus, with high efficiency, stability, strong specificity and other characteristics, can meet the needs of different users.

    Product Features:

    1.Short time: the detection time is short and can be used with Bioer one-step method virus nucleic acid extraction kit.

    2.Monitorable: the whole process of sampling, extraction and PCR detection can be monitored

    3.High efficiency and stability: specially designed for African swine fever virus, with good practicality, stable storage and transportation

    4.Strong versatility: Suitable for all kinds of PCR detection system

    Experimental data:

    Case 1

    Nucleic acid was extracted from pig whole blood samples containing African swine fever virus using Bioer MagaBio Plus virus DNA extraction kit II. After gradient dilution of nucleic acid (10-100,000 times), Bioer ASFV real-time PCR detection kit was used for detection. The results were shown in Figure 1 and Figure 2:

    figure 1

    Figure 2

    Case 2

    The nucleic acid containing ASFV samples was extracted with the Simply P virus DNA/RNA extraction kit of Bioer Technology, and then detected with the Bioer ASFV real-time PCR detection kit and the other detection reagent of C Company in the market. The results were shown in Figure 3 and Figure 4:

    Bioer Technology

    Figure 3

     

    C company

    Figure 4

    The results showed that Bioer ASFV real-time PCR detection reagent detected one more sample than other reagents from C company, indicating that Bioer ASFV real-time PCR detection reagent kit is more sensitive and has a stronger gray area sample detection ability in use, which reduces the risk of missing detection.

    Manual download
Privacy clause

Respect the user's privacy is a basic policy of Hangzhou Bioer user service. Hangzhou Boier will not disclosure user information to third parties or disclose their registration and preservation of non disclosure in Hangzhou Bioer platform, except in the following situations: (1)User's improper behavior caused leakage of privacy information ; (2)Caused by network, hacker attack, computer virus, government regulation, the reasons of the leakage, lost, stolen or tampered with other relevant legal requirements; (3)Law-enforcement agency asked Hangzhou Bioer to provide privacy information of the user; (4)Emergency situation when public life and property security is under threate.

Exemption clause

Hangzhou Bioer technology does not guarantee the accuracy, integrity and reliability of any content on this website and any content that may use these results. Hangzhou Bioer technology and related people can not guarantee that you can enter, browse and use this website at any time; Hangzhou Bioer technology on this website and its contents can not use and do not take any responsibility. The site links to other websites that Hangzhou itself is not recognized or undertake other Bioer technology content or the use of responsibility. Hangzhou Bioer technology and related people to enter, browse and use of the site, from the website to download any content or by any link to this site to other sites caused by viruses or other destructive programs on your computer system and any other software and hardware, IT system or property damage or loss does not bear any responsibility. Hangzhou Bioer technology and the relevant people do not bear any responsibility caused by the third party using illegal means to obtain the password, data and content into the site of any direct and indirect damage or loss . The final interpretation belong to Hangzhou Bioer Technology Co. Ltd. 

Hangzhou Bioer reserves the right to correct, modify and update this statement at any time.

Copyright

This website from Hangzhou Bioer Technology Co. Ltd. (hereinafter referred to as "Hangzhou Bioer") the creation of any content of this website (including but not limited to text, data, graphics, images, voice or video) are copyright or related rights belong to Hangzhou Bioer. Hangzhou Bioer or related rights without prior written permission, you shall not in any way without permission to copy, reconstruction, spread, publishing, reprint, repost or display the contents of this website. Any unauthorized use of this site may violate the "Copyright Law of People's Republic of China " and other relevant laws and regulations and international conventions, Hangzhou Bioer fully pursue appropriate legal responsibility right.

Contact Us

Address: 1192 Bin An Rd, Hi-tech (Binjiang)District,Hangzhou,310053,P. R. China

Tel:0571-87774567